Winpact Parallel Fermentation System is the ultimate and true parallel system for your parallel experiment. Whether you need to run two identical experiments or different experiments at once, the duo heating system allows you to run two thermostat heating, two dry heating or one thermostat and one dry heating simultaneously. This state-of-the-art fermenter/bioreactor is constructed with the upmost versatility and flexibility to work with all types and sites of Winpact vessels. The remote control software can control up to 16 fermentors for true parallel operation.
Controller | Duo heating system controller, Built-in rotameter, 4 built-in pump heads |
Control Panel | 10.4" color touch screen interface |
Communication port | Remote software control through Ethernet, up to 16 systems per PC, Data export through USB port, Analog AUX port for system extension |
Program storage | Up to 59,994 process programs |
Log data storage | Up to 100 process monitoring data files |
Cabinet material | ABS front panel and painted iron housing |
Dimension | Footprint: W x L = 15.75" x 21.61" (400 mm x 549 mm); Height: 29.14" (740 mm) |
Rated voltage | 220V~; 50/60 Hz, 10A, 2000W |
Weight | Approx. 114.6 lb (52 kg) |
Inlet gas flow-meter | 0,0.1-1 LPM (500 ml); 0, 0.2-2.5 LPM (1 L); 0, 1-10 LPM (3, 5 L); 0, 2-25 LPM (10 L); 0, 6-50 LPM (15, 20 L) |
Sparger | L-shape (500ml, 1L); Ring sparger (3L and above); Micro-sparger (C type vessels); Center-located sparger (solid state) |
Baffle | 316L stainless steel baffles • 0.5-3L vessel: fixed, unmovable • 5L and above vessel: removable |
Heating | 1. Thermostat system: built-in heat exchanger (550W heater, water circulation pump) 2. Dry heating system : external devices (heating blanket or heating base unit) |
Cooling | Built-in water module and external water circulator (optional) |
Range | FS-V-A/ B / SA05P series: 5℃ (41℉) above coolant up to 60℃ (140℉) - FS-V-C series (Double Jacketed): 5℃ (41℉) above coolant up to 60℃ (140℉) - FS-V-C series (Single Wall): without temp control - FS-V-D series : 5℃ (41℉) above coolant up to 90℃ (194℉) * Antifreeze is required to apply |
Probe | Platinum RTD probe (PT-100), non autoclavable |
Control mode | Manual or programmable 15-step PID control |
Drive | Removable top brushless motor |
Speed range | a. For Pitched blade impeller: 30-300 rpm b. For Rushton impeller: 30-1800 rpm(0.5, 1L); 30-1200 rpm(3, 5L); 30-1000 rpm(10L); 30-700 rpm(15, 20L) c. For Broken type/Spiral type/Anchor type impellers (only for FS-V-SA05 vessel): 1 – 60 rpm** |
Resolution | 1 rpm increment |
Impeller | 2 impellers for 0.5-1 L vessel and 0.5-5 L Double Jacketed Vessel 3 impellers for 3 L vessel and above; for 10 L Double Jacketed Vessel |
Impellers Customizable | Yes |
Control mode | Manual or programmable 15-step PID control with adjustable deadband |
pH Range | 0 -14 (2-12 for maximum precision) |
pH Resolution | 0.01 pH |
pH Probe | Gel-filled electrode, autoclavable |
pH Control mode | Manual/acid start/progrmmable 15-step PID control |
DO Range | 0-200%, Control range: 0-100%, adjustable |
DO Resolution | 0.1% |
DO Probe | Polarographic DO sensor; autoclavable |
Control mode | • 2-stage DO cascade response a. Increase or decrease agitation speed b. Supply external oxygen source (oxygen enrichment module required, optional device) c. Adjust DO level using gas mixing control (gas mixing station module required, optional device) • Substrate feeding strategy • DO Stat with smart feeding technology |
ORP (optional) Measurement range | ± 2000 mV |
ORP (optional) Resolution | 1 mV |
ORP (optional ) Probe | Gel-filled electrode: autoclavable |
Foam / level Probe | 316L stainless steel protector with insulated PTFE tube; autoclavable, adjustable sensitivity control |
Foam/ level Control mode | Foam: on/off switch Level: on/off switch control with wet/dry probe set up |
Peristaltic pump | 4 built-in Watson Marlow pumps per vessel (total 8); Total 4 external pumps expandable: • 2 external pumps: MU-D series required (optional) • 2 external pumps: 4-20mA or DC 0-10V analog input **The minimum speed varies from 1-5 rpm depending on the medium viscosity. |
Pump Motor type | Precise stepping motor; minimum speed is 1 rpm |
Pump Speed range | 0 - 65 rpm |
Pump Resolution | 1 rpm |
Pump Control mode | Manual or programmable 15-step feeding control; pump can be assigned for acid, base, antifoam and substrate |
Exhaust Device type | 316L stainless steel condenser |
Power Source | 210-230V, 50-60Hz with electrical safety cutoff switch |
Water source | 0.4-1 bar (5.8-14.5 psi); water supplied to fermentors should be at least 15°C below the set operating temperature |
Air source | 0.5-2 bar, must be dry, oil-free and filtered. |
Sterilization | Autoclave; size of the autoclave's inner chamber must be able to accommodate vessel with condenser attached |
The most versatile, price and space-saving fermentation system is now available from our Winpact fermentor product line-the Winpact One Fermentation System.
Winpact One is not only compact in size but also provides all the necessary tools as a standard bioreactor. The duo heating system allows you to choose any vessel type up to 10L for any application needs. The optional expansion module allows you to add additional devices to enhance the capability of the system. All necessities such as temperature, anti-foam, pH and DO probe are all included in the standard package.
Controller | Duo heating system controller, Built-in rotameter, 3 built-in pump heads |
Control panel | 8" Color touch-screen interface |
Communication port | Remote software control through Ethernet, up to 16 systems per PC, Data export through USB port , Analog AUX port for system extension |
Program storage | Up to 59,994 process programs |
Log data storage | Up to 100 process monitoring data files |
Cabinet material | ABS front panel and painted iron housing |
Dimension | Footprint: W x L = 9.84" x 20.08" (250 mm x 510 mm), Height: 19.69" (500 mm) |
Rated voltage | 110V~/220V; 50/60 Hz, 10A |
Weight | Approx. 61.73 lb (28 kg) |
Inlet gas flow-meter | 0,0.1-1 LPM (0.5 L), 0, 0.2-2.5 LPM (1 L), 0, 1-10 LPM (3, 5 L), 0, 2-25 LPM (10 L) |
Sparger | L-shape (500ml, 1L); Ring sparger (3L and above); Micro-sparger (C type vessels) |
Baffle | 316L stainless steel baffles • 0.5-3L vessel: fixed, unmovable • 5L and above vessel: removable |
Heating | 1. Thermostat system: built-in heat exchanger (550W heater, water circulation pump) 2. Dry heating system (heating blanket or heating base unit) |
Cooling | Built-in water module and external water circulator (optional) |
Range | - FS-V-A/ B / SA05P series: 5℃ (41℉) above coolant up to 60℃ (140℉) - FS-V-C series (Double Jacketed): 5℃ (41℉) above coolant up to 60℃ (140℉) - FS-V-C series (Single Wall): without temp control - FS-V-D series : 5℃ (41℉) above coolant up to 90℃ (194℉) * Antifreeze is required to apply |
Probe | Platinum RTD probe (PT-100), non autoclavable |
Temperature Control Mode | Manual or programmable 15-step PID control |
Drive | Removable top brushless motor |
Speed range | a. For Pitched blade impeller: 30-300 rpm b. For Rushton impeller: 30-1800 rpm(0.5, 1L); 30-1200 rpm(3, 5L); 30-1000 rpm(10L) |
Resolution | 1 rpm increment |
Impeller | 2 impellers for 0.5-1 L vessel and 0.5-5 L Double Jacketed Vessel 3 impellers for 3 L vessel and above; for 10 L Double Jacketed Vessel |
Impeller Customizable | Yes |
Control mode | Manual or programmable 15-step PID control |
pH Range | 0 -14 (2-12 for maximum precision) |
pH Resolution | 0.01 pH |
pH Probe | Gel-filled electrode, autoclavable |
pH Control mode | Manual/acid start/programmable 15-step PID control with adjustable deadband **pH Stat with smart feeding technology |
DO Range | 0-200%, Control range: 0-100%, adjustable |
DO Resolution | 0.1% |
DO Probe | Polarographic DO sensor; autoclavable |
DO Control mode | • DO cascade response: 1-stage or 2-stage** a. Increase or decrease agitation speed **b. Supply external oxygen source (oxygen enrichment module required, optional device) **c. Adjust DO level using gas mixing control (gas mixing station module required, optional device) • Substrate feeding strategy • **DO Stat with smart feeding technology |
ORP (optional) Measurement range | ± 2000 mV |
ORP (optional) Resolution | 1 mV |
ORP* (optional) Probe | Gel-filled electrode: autoclavable |
Foam / level Probe | 316 L stainless steel protector with insulated PTFE tube, autoclavable, adjustable sensitivity control |
Foam / level Control mode | Foam: on/off switch Level: on/off switch control with wet/dry probe set up |
Peristaltic pump | built-in Watson Marlow pumps; 1 external pump expandable: MU-D series required (optional); **2 external pumps expandable: • 1 external pump: MU-D series required (optional) • 1 external pump: 4-20mA or DC 0-10V analog input |
Pump Motor type | Precise stepping motor; minimum speed is 1 rpm |
Pump Speed range | 0 - 65 rpm |
Pump Resolution | 1 rpm |
Pump Control mode | Manual or programmable 15-step feeding control; pump can be assigned for acid, base, antifoam and substrate; **flow rate & total volume calculation |
Exhaust Device type | 316 L stainless steel condenser |
Power source | 100-120V / 210-230V, 50-60Hz with electrical safety cutoff switch |
Water source | 0.4-1 bar (5.8-14.5 psi); water supplied to fermentors should be at least 15°C below the set operating temperature |
Air source | 0.5-2 bar, must be dry, oil-free and filtered |
Sterilization | Autoclave; size of the autoclave's inner chamber must be able to accomodate vessel with condenser attached |
Winpact Evo Fermentation System is the one-side version of Winpact Parallel Fermentation System yet offers cutting-edge software. It retains all the great features from FS-05 such as duo heating system,16-system control from a remote computer, 5 types of autoclavable glass vessels ranging from 0.5L to 20L. We also dramatically enhanced the functionalities and capabilities of this newly developed controller, including the versatility to accommodate solid state bioreactors.
Controller | Duo heating system controller, Built-in rotameter, 4 built-in pump heads |
Control panel | 10.4” color touch-screen Interface (Resolution: 800 x 600 pixels) |
Communication port | emote software control through Ethernet, up to 16 systems per PC, Data export through USB port, Analog AUX port for system extension |
Program storage | Up to 59,994 programs for different kinds of condition |
Log data storage | Up to 100 process monitoring data files |
Cabinet material | ABS front panel and painted iron housing |
Dimension | Footprint: W x L = 15.75" x 23.62" (400 mm x 600 mm); Height: 29.14" (740 mm) |
Rated voltage | 110V~/220V~; 50/60 Hz, 10A |
Weight | Approx. 88.18 lb (40 kg) |
Inlet gas flow-meter | 0, 0.4-5 LPM (0.5, 1 L); 0, 1-10 LPM (3, 5 L); 0, 2-20 LPM (10 L); 0, 4-50 LPM (15, 20 L) |
Sparger | L-shape (500ml, 1L); Ring sparger (3L and above); Micro-sparger (C type vessels); Center-located sparger (solid state) |
Baffle | 316L stainless steel baffles • 0.5-3L vessel: fixed, unmovable • 5L and above vessel: removable |
Heating | 1. Thermostat system: built-in heat exchanger (550W heater, water circulation pump) 2. Dry heating system (heating blanket or heating base unit) |
Cooling | Built-in water module and external water circulator (optional) |
Temperature Range | - FS-V-A/ B / SA05P series: 5℃ (41℉) above coolant up to 60℃ (140℉) - FS-V-C series (Double Jacketed): 5℃ (41℉) above coolant up to 60℃ (140℉) - FS-V-C series (Single Wall): without temp control - FS-V-D series : 5℃ (41℉) above coolant up to 90℃ (194℉) * Antifreeze is required to apply |
Temperature Probe | Platinum RTD probe (PT-100), non autoclavable |
Temperature Control mode | Manual or programmable 15-step PID control |
Drive | Removable top brushless motor (M3 for 0.5 L, 1 L; M2 for 3~20 L; M4 for solid state) |
Speed range | a. For Pitched blade impeller: 30-300 rpm b. For Rushton impeller: 30-1800 rpm(0.5, 1L); 30-1200 rpm(3, 5L); 30-1000 rpm(10L); 30-700 rpm (15, 20L) c. For Broken type/Spiral type/Anchor type impellers (only for FS-V-SA05 vessel): 1 – 60 rpm** |
Resolution | 1rpm increment |
Impeller | 2 impellers for 0.5 L &1 L vessel and 0.5-5 L Double Jacketed Vessel 3 impellers for 3 L vessel and above; for 10 L Double Jacketed Vessel Note: customized impellers are available upon ordering |
Control mode | Manual or programmable 15-step PID control |
pH Range | 0 -14 (2-12 for maximum precision) |
pH Resolution | 0.01 pH |
pH Probe | Gel-filled electrode, autoclavable |
pH Control mode | Manual/programmable 15-step PID control with adjustable deadband pH Stat with smart feeding technology |
DO Range | 0-200%, Control range: 0-100%, adjustable |
DO Resolution | 0.10% |
DO Probe | Polarographic DO sensor; autoclavable |
DO Control mode | 2-stage DO cascade response a. Increase or decrease agitation speed b. Supply external oxygen source (oxygen enrichment module required, optional device) c. Adjust DO level using gas mixing control (gas mixing station module required, optional device) Substrate feeding strategy DO Stat with smart feeding technology |
ORP(optional) Measurement range | ± 2000 mV |
ORP(optional) Resolution | 1 mV |
ORP(optional) Probe | Gel-filled electrode: autoclavable |
Foam / level Probe | 316 L stainless steel protector with insulated PTFE tube, autoclavable, adjustable sensitivity control |
Foam/level Control mode | Foam: on/off switch Level: on/off switch control with wet/dry probe set up |
Peristaltic pump | 4 built-in Watson Marlow pumps; 2 external pumps expandable: • 1 external pump: MU-D series required (optional) • 1 external pump: 4-20mA or DC 0-10V analog input **The minimum speed varies from 1-5 rpm depending on the medium viscosity. |
Pump Motor type | Precise stepping motor; minimum speed is 1 rpm |
Pump Speed range | 0 - 65 rpm |
Pump Resolution | 1 rpm |
Pump Control mode | Manual or programmable 15-step feeding control; pump can be assigned for acid, base, antifoam and/or substrate; pump can calculate flow rate and total volume |
Exhaust Device type | 316L stainless steel condenser |
Power source | 100-120V / 210-230V, 50-60Hz with electrical safety cutoff switch |
Water source | 0.4-1 bar (5.8-14.5 psi); water supplied to fermentors should be at least 15°C below the set operating temperature |
Air source | 0.5-2 bar, must be dry, oil-free and filtered |
Sterilization | Autoclave; size of the autoclave's inner chamber must be able to accomodate vessel with condenser attached |